PRODUCTS
Wire & Cable, Cable Accessories, Telecom Accessories, Energy Saving Lamp(CFL)...
KT0682 RG6 Dual 60% Bonded PVC CM
 
View Larger
KT0682 RG6 Dual 60% Bonded PVC CM
RG6 Dual 60% Bonded PVC CM
Construction Parameters:
  Inner Conductor 0.040"/1.02mm/18AWG Copper-Clad Steel
  Dielectric 0.180"/4.57mm Foamed PE        
  Shield 1 0.187"/4.75mm Bonded Aluminum Polyproylene
  Shield 2 Aluminum braid wire 60% coverage  
  Jacket 0.268"±0.006"/6.81±0.15mm PVC CM
  Jacket Thickness 0.030"/0.76mm
  Application For Use in Longer CATV Run Lengths
     
Electrical Characteristics:
  Inner Cond. Resistance The Max. at 20 shall be <  87 Ω/km           26.6Ω/1000ft   
  Capacitance 52 ±3 pF/m             15.9 ±0.9 pF/ft
  Impedance 75 ± 3 Ω
  Return loss  between 5 and 1000MHz: > 22dB
  Velocity of Propagation  0.85
  Sparker Test (VAC) 4
     
Attenuation(20℃):
Frequency 
           (MHZ)            
Max Attenuation
(dB/100ft)
Max Attenuation 
(dB/100m)
5 0.58  1.90 
55 1.60  5.25 
83 1.95  6.40 
187 2.85  9.35 
211 3.05  10.00 
250 3.30  10.82 
300 3.55  11.64 
350 3.85  12.63 
400 4.15  13.61 
450 4.40  14.43 
500 4.66  15.29 
550 4.90  16.08 
600 5.10  16.73 
750 5.65  18.54 
865 6.10  20.01 
1000 6.55  21.49 
     
Mechanical and Envrionmental Properties
  Cable bend radius 10 times the cable diameter
  Operating Temp Range  (PVC) -20  to 60
  Cable diamensions 0.268"±0.006"/6.81±0.15mm PVC